Force raw8 for debayering

$
0
0
Hi, I have a Basler camera that outputs bayer pattern images in format7_mode1 mode. However, when I set raw8 for the format7_color_coding parameter, then it fails to be set, and mono8 is used instead. Therefore, the image_proc node cannot debayer the images, because it thinks they are simply grayscale, instead of bayer, as they actually are. Everything works in coriander (see [coriander_bayer.png](/upfiles/13413943973522718.png)). The output of the camera1394 node is [ INFO] [1341392664.941249990]: using default calibration URL [ INFO] [1341392664.941737294]: camera calibration URL: file:///home/enrique/.ros/camera_info/camera.yaml [ERROR] [1341392664.942107239]: Unable to open camera calibration file [/home/enrique/.ros/camera_info/camera.yaml] [ WARN] [1341392664.942363881]: Camera calibration file /home/enrique/.ros/camera_info/camera.yaml not found. [ INFO] [1341392665.615791969]: Found camera with GUID 305300013759c6 [ INFO] [1341392665.616241698]: camera model: Basler A102fc [ INFO] [1341392665.621517490]: Format7 unit size: (2x2), position: (2x2) [ INFO] [1341392665.621664656]: Format7 region size: (1388x1038), offset: (0, 0) [ERROR] [1341392665.624025892]: Color coding raw8 not supported by this camera [ INFO] [1341392665.636889941]: using default calibration URL [ INFO] [1341392665.637584961]: camera calibration URL: file:///home/enrique/.ros/camera_info/00305300013759c6.yaml [ERROR] [1341392665.638324312]: Unable to open camera calibration file [/home/enrique/.ros/camera_info/00305300013759c6.yaml] [ WARN] [1341392665.639039116]: Camera calibration file /home/enrique/.ros/camera_info/00305300013759c6.yaml not found. [ INFO] [1341392665.639805838]: [00305300013759c6] opened: format7_mode1, 15 fps, 400 Mb/s [ INFO] [1341392665.640524806]: camera calibration URL: package://cameras_cirs/calibration/basler_a102fc/format7_mode1/00305300013759c6.yaml The message Color coding raw8 not supported by this camera of the output, is generated in modes.cpp file. IMHO I think the best way to solve this is to allow the image_proc node to debayer mono8 images, so cameras that call mono8 to what should be raw8 are supported. How can I force to set the raw8 encoding, or just debayer the images? Thanks in advance. Below you can see the launch and (parameters/config) yaml files I'm using to run the camera driver. Enrique **basler_a102fc_format7_mode1.yaml** # Example camera parameters (for Basler A102fc) # Parameters (no lens required/used) guid: 00305300013759c6 # (defaults to first camera on bus) iso_speed: 400 # IEEE1394a video_mode: format7_mode1 # 1388x1038 @ 15fps bayer pattern frame_rate: 15 # max fps (Hz) format7_color_coding: raw8 # for bayer (we can use others, even rgb8 directly) # With raw8, we don't need to configure bayer pattern and method, actually we # cannot change them bayer_pattern: gbrg #bayer_method: HQ auto_brightness: 3 # Manual (3) brightness: 0 # Is better to increase gain than shutter speed, becuase gain produce salt&pepper # noise, while shutter speed produce motion blur, which is harder to deal with. auto_gain: 3 # Manual (3) gain: 512 # dB unavailable # See comment above wrt to gain and shutter speed setting. auto_shutter: 3 # Manual (3) shutter: 356 # time (ms) unavailable; value for sunlight auto_white_balance: 3 # Manual (3) white_balance_BU: 112 white_balance_RV: 64 frame_id: basler_a102fc camera_info_url: package://cameras_cirs/calibration/basler_a102fc/format7_mode1/${NAME}.yaml **basler_a102fc.launch**

Viewing all articles
Browse latest Browse all 34

Trending Articles



<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>